Type: MFMR |
| Magnetic force microscopy - Reflex coating |
|
NanoWorld Pointprobe® MFM probes are designed for magnetic force microscopy. The force constant and the special hard magnetic tip-side coating of the MFM type are optimised for this type of application. This type of probe yields a very high force sensitivity, while simultaneously enabling tapping and lift mode operation.
All probes of the Pointprobe® series are made from monolithic silicon which is highly doped to dissipate static charge. They are chemically inert and offer a high mechanical Q-factor for high sensitivity. The tip is shaped like a polygon based pyramid with a height of 10-15 µm.
Additionally this probe offers unique features: Soft magnetic samples may be influenced by the tip magnetization ! The reflex coating on the detector side of the cantilever enhances its reflectivity and prevents light from interfering within the cantilever. |
| Technical Data | Value | Range* | ![]() |
| Thickness | 3 µm | 2.5 - 3.5 | |
| Mean Width | 28 µm | 22.5 - 32.5 | |
| Length | 225 µm | 220 - 230 | |
| Force Constant | 2.8 N/m | 1.2 - 5.5 | |
| Resonance Frequency | 75 kHz | 60 - 90 | |
| Order Code | Quantity | Data Sheet | |
| MFMR-10 | 10 | yes | |
| MFMR-20 | 20 | yes | |
| MFMR-50 | 50 | no | |
| MFMR-W | 380 | yes | |
* Typical values |
|||
| Hard Magnetic Coating |
| Hard magnetic coating is an approximately 40 nm thick cobalt alloy coating on the tip-side of the cantilever leading to a permanent magnetization of the tip with the direction usually along the tip axis. We recommend to magnetize the tip by means of a strong magnet (e.g. a NdFeB magnet, a few millimeters in size). As the coating is almost stress free the bending of the cantilever due to stress is less than 2°. |
| Reflex Coating |
| Reflex coating is an approximately 30 nm thick aluminium coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of 2.5. Furthermore it prevents light from interfering within the cantilever. As the coating is almost stress free the bending of the cantilever due to stress is less than 2°. |
|
For more information contact: info@nanoworld.com
| |
|
POINTPROBE® is a registered trademark of NANOWORLD AG TappingMode is a trademark of Digital Instruments Inc. GelPak® is a registered trademark of Vichem Corporation All data are subject to change without notice. |
NanoWorld AG Rue Jaquet-Droz 1 Case Postale 216 CH-2002 Neuchâtel Switzerland www.nanoworld.com |